PA6 BKV 30 FN00 000000µÂ¹úÀÊÊ¢Durethan 30%²£ÏËÔöÇ¿ÎÞ±×èȼÄáÁú6ËÜÁÏ£¨18024445500£©
PA 6, 30 % glass fibers, injection molding, halogen free flame retardant
ISO Shortname: ISO 1874-PA 6, GFHR, 14-110, GF30; ISO 1043-PA GF FR (30+40+72)
Property Test Condition Unit Standard guide value
d.a.m. cond.
Rheological properties
C Melt volume-flow rate 260 ¡ãC; 2.16 kg cm³/(10 min) ISO 1133-1 23¡¡
C Molding shrinkage, parallel 60x60x2; 280 ¡ãC / MT 80 ¡ãC; 600 bar % ISO 294-4 0.22¡¡
C Molding shrinkage, transverse 60x60x2; 280 ¡ãC / MT 80 ¡ãC; 600 bar % ISO 294-4 0.62¡¡
Post- shrinkage, parallel 60x60x2; 120 ¡ãC; 4 h % ISO 294-4 0.08¡¡
Post- shrinkage, transverse 60x60x2; 120 ¡ãC; 4 h % ISO 294-4 0.18¡¡
Mechanical properties (23 ¡ãC/50 % r. h.)
C Tensile modulus 1 mm/min MPa ISO 527-1,-2 10800 6700
C Tensile Stress at break 5 mm/min MPa ISO 527-1,-2 150 90
C Tensile Strain at break 5 mm/min % ISO 527-1,-2 3.0 6.1
C Charpy impact strength 23 ¡ãC kJ/m² ISO 179-1eU 60 65
C Charpy notched impact strength 23 ¡ãC kJ/m&sup2; ISO 179-1eA <10¡¡
C Charpy notched impact strength -30 ¡ãC kJ/m&sup2; ISO 179-1eA <10¡¡
Izod impact strength 23 ¡ãC kJ/m&sup2; ISO 180-1U 55 55
Izod notched impact strength 23 ¡ãC kJ/m&sup2; ISO 180-1A <10¡¡
Izod notched impact strength -30 ¡ãC kJ/m&sup2; ISO 180-1A <10¡¡
Flexural modulus 2 mm/min MPa ISO 178-A 9800 6000
Flexural strength 2 mm/min MPa ISO 178-A 210 140
Flexural strain at flexural strength 2 mm/min % ISO 178-A 2.7 4.6
Flexural stress at 3.5 % strain 2 mm/min MPa ISO 178-A¡¡128
Thermal properties
C Melting temperature 10 ¡ãC/min ¡ãC ISO 11357-1,-3 224¡¡
C Temperature of deflection under load 1.80 MPa ¡ãC ISO 75-1,-2 204¡¡
C Temperature of deflection under load 0.45 MPa ¡ãC ISO 75-1,-2 218¡¡
Vicat softening temperature 50 N; 120 ¡ãC/h ¡ãC ISO 306 210¡¡
C Coefficient of linear thermal expansion, parallel 23 to 55 ¡ãC 10-4/K ISO 11359-1,-2 0.22¡¡
C Coefficient of linear thermal expansion, transverse 23 to 55 ¡ãC 10-4/K ISO 11359-1,-2 0.81¡¡
C Burning behavior UL 94 (1.6 mm)¡¡Class UL 94 V-0¡¡
Burning behavior UL 94 0.75 mm Class UL 94 V-0¡¡
C Burning behavior UL 94-5V 1.6 mm Class UL 94 5VA¡¡
C Oxygen index Method A % ISO 4589-2 32.1¡¡
Glow wire test (GWFI) 0.8 mm ¡ãC IEC 60695-2-12 960¡¡
Glow wire test (GWFI) 1.5 mm ¡ãC IEC 60695-2-12 960¡¡
Glow wire test (GWFI) 3.0 mm ¡ãC IEC 60695-2-12 960¡¡
Glow wire test (GWIT) 0.8 mm ¡ãC IEC 60695-2-13 775¡¡
Glow wire test (GWIT) 1.5 mm ¡ãC IEC 60695-2-13 775¡¡
Glow wire test (GWIT) 3.0 mm ¡ãC IEC 60695-2-13 800¡¡
Electrical properties (23 ¡ãC/50 % r. h.)
C Electric strength 1 mm kV/mm IEC 60243-1 36.7¡¡
C Comparative tracking index CTI Solution A V IEC 60112 600¡¡
Other properties (23 ¡ãC)
C Water absorption (Saturation value) Water at 23 ¡ãC % ISO 62 5¡¡
C Water absorption (Equilibrium value) 23 ¡ãC; 50 % RH % ISO 62 1.5¡¡
C Density¡¡kg/m&sup3; ISO 1183 1427¡¡
Processing conditions for test specimens
C Injection molding-Melt temperature¡¡¡ãC ISO 294 260¡¡
C Injection molding-Mold temperature¡¡¡ãC ISO 294 80¡¡
Processing recommendations
Drying temperature dry air dryer¡¡¡ãC - 80¡¡
Drying time dry air dryer¡¡h - 2-6¡¡
Residual moisture content¡¡% Acc. to Karl Fischer¡¡0.03-0.07¡¡
Melt temperature (Tmin - Tmax)¡¡¡ãC - 250-270¡¡
Mold temperature¡¡¡ãC - 80-100¡¡
C These property characteristics are taken from the CAMPUS plastics data bank and are based on the international catalogue of basic data for plastics according to ISO 10350. |